Product Details:
Payment & Shipping Terms:
|
Name: | Vehicle Testing Load Cell | Accurracy: | 0.025~0.03% |
---|---|---|---|
Material: | Steel | Capacity: | 0.5-5t |
Load Direction: | Compression | Application: | Analog Load Cell |
Features;
· | Stainless steel IP68 compression load cell |
· | Hermetically sealed |
· Suitable for vehicle and hopper scales and vehicle | |
testing facilities | |
· Built in surge arrestors | |
· | High accuracy |
· Current calibrated (sc-option) |
Available models
Capacity | Accuracy | Full article description |
0.5t | C3 Excluded from OIML | BM14C-C3-0.5t-15B-SC |
1t | C3 Excluded from OIML | BM14C-C3-1t-15B-SC |
2t | C3 Excluded from OIML | BM14C-C3-2t-15B-SC |
3t | C3 Excluded from OIML | BM14C-C3-3t-15B-SC |
5t | C3 Excluded from OIML | BM14C-C3-5t-15B-SC |
10t | C3/C4 | BM14C-C3/C4-10t-15B-SC |
20t | C3/C4 | BM14C-C3/C4-20t-15B-SC |
25t | C3/C4 | BM14C-C3/C4-25t-15B-SC |
30t | C3/C4 | BM14C-C3/C4-30t-15/18B-SC |
40t | C3/C4 | BM14C-C3/C4-40t-15/18B-SC |
50t | C3/C4 | BM14C-C3/C4-50t-15/18B-SC |
Detailed specifications BM14C
Accuracy class | C3 | OIML R60 C3 | OIML R60 C4 | ||||
Output sensitivity ( = FS ) | mV/V | 2.0 ± 0.002 | |||||
Maximum capacity ( Emax ) | t | 0.5, 1, 2, 3, 5 | 10, 20, 25, 30, 40, 50 | ||||
Max.number of load cell intervals | nLC | 3000 | 4000 | ||||
Ratio of min. LC verification interval | Y = Emax / vmin | 10000 | 15000 | ||||
Combined Error | %FS | ≤± 0.023 | ≤± 0.0174 | ||||
Minimum dead load | Of Emax | 0% | |||||
Safe overload | of Emax | 150 % | |||||
Ultimate overload | of Emax | 300 % | |||||
Zero balance | of FS | < ± 1.0 % | |||||
Excitation, recommended voltage | V | 5 ~ 12 | |||||
Excitation maximum | V | 18 | |||||
Input resistance | Ω | 700 ± 7 | |||||
Output resistance | Ω | 703 ± 4 | |||||
Insulation resistance | MΩ | ≥5000 ( at 50VDC ) | |||||
Compensated temperature | °C | -10 ~+40 | |||||
Operating temperature | °C | -35 ~ +65 | |||||
Storage temperature | °C | -40 ~ +70 | |||||
Element material | Stainless steel | ||||||
Ingress Protection (acc. to EN 60529) | IP68 | ||||||
Recommended torque on fixation | Nm | - | |||||
ATEX classification (optional) | II3G Ex nA IIC T4 Gc | II3D Ex tc IIIC T73°C Dc | |||||
II1G Ex ia II1C T4 | II1D Ex iaD 20 T73°C | ||||||
Wiring
Wiring:
Shielded, 4 conductor cable.
Cable diameter: Ø5mm
Standard cable length for all C3: 15m and for C4 above 30t: 18m.
Shield not connected to element
Hot Sales Models:
BM14C-C3-0.5t-13B6
BM14C-C3-1t-13B6
BM14C-C3-2t-13B6
BM14C-C3-3t-13B6
BM14C-C3-5t-13B6
BM14C-C3-10t-13B6
BM14C-C3-20t-13B6
BM14C-C3-25t-13B6
BM14C-C3-30t-13B6
BM14C-C3-40t-13B6
BM14C-C3-50t-13B6